Luminaire Type:
Catalog Number
(autopopulated):
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2011-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 10/08/13. Specifications subject to change without notice.
PAGE 1 OF 3
LGFLP-6-SHOWER
Gotham Architectural Downlighting
Compact Fluorescent Downlights
6” LGFLP
Non-Conductive Shower Light
Lensed Low Profile
Triple-Tube Lamp
FEATURES ORDERING INFORMATION NOTES
OPTICAL SYSTEM
• Aluminum upper reflector coated with highly reflective white paint provides high
efficiency and an evenly illuminated aperture appearance.
• Lens door made of impact-modified acrylic provides excellent durability and
light transmission. “Dead front” shower light for added safety.
MECHANICAL SYSTEM
• 16-gauge galvanized steel mounting/plaster frame. Maximum 1-1/4” ceiling
thickness.
• 16-gauge galvanized steel mounting bars with continuous 4” vertical adjust-
ment are shipped pre-installed. Post-installation adjustment possible without
the use of tools from above or below ceiling.
• Galvanized steel junction box with hinged access covers and spring latch. Two
combination 1/2”-3/4” and three 1/2” knockouts for straight-through conduit
runs. Capacity: 8 (4 in, 4 out) No. 12 AWG conductors rated for 90°C.
• Low-profile design allows for 4-5/16” fixture depth above ceiling.
ELECTRICAL SYSTEM
• Galvanized steel lampholder housing.
• Horizontally mounted, four-pin, positive-latch, thermoplastic socket(s).
• Class P, thermally protected, high-power-factor electronic ballast(s) mounted to
the junction box.
LISTING
• Fixtures are UL Listed for thru-branch wiring, non-IC recessed mounting and wet
locations. Listed and labeled to comply with Canadian standards.
• IP65 rated.
WARRANTY
• 1-year limited warranty. Complete warranty terms located at:
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
EXAMPLE: LGFLP 1/26TRT 6DFR MVOLT
Series Wattage/Lamp Door frame Voltage Ballast Options
LGFLP 1/18TRT
1/26TRT
1
1/32TRT
1/42TRT
6DFR Dead (non-conduc-
tive) front regressed
6DFD Dead (non-conduc-
tive) front drop
MVOLT
2
120
277
347
(blank) Electronic ballast
ECOS
3
EcoSystem
®
electronic dimming
ballast. Minimum dimming
level 5%
ADEZ
3, 4
Advance Mark 10
®
electronic
dimming ballast. Minimum
dimming level 5%
ADZT
3, 4
Advance Mark 7
®
electronic
dimming ballast. Minimum
dimming level 5%
ELR
5
Emergency battery pack, remote test switch
ELRHL
5
High lumen output emergency battery pack,
remote test switch provided
GMF
3
Single, slow-blow fuse
GLR
3
Single, fast-blow fuse
TRW
White painted flange
DS Dual switching
CP
6
Chicago plenum
WLP
With 3500 K lamp (shipped separately)
NEPP Interface for Sensor Switch
®
nLight
®
network
with integral power supply. Refer to TN-623-01.
DFD
DFR
ORDERING NOTES
1. Will also operate 26DTT 4-PIN lamp.
2. Multi-volt electronic ballast capable of operating on any voltage from 120V
through 277V, 50 or 60 Hz.
3. Not available with 347V.
4. Not available with MVOLT.
5. For dimensional changes, refer to TECH-140.
6. Not available with emergency options.
Comments to this Manuals